HVAC Fundamentals: Heat Pumps

A heat pump is a refrigeration gadget used to switch heat from one room or area to another. The Heat pump new plymouth pump is designed to take heat from a medium-temperature supply, such as out of doors air, and convert it to higher-temperature heat for distribution within a structure. By way of a specifically designed reversing valve, the pump may also extract heat from the indoor air and expel it outdoors.

Because a heat pump system uses the reverse-cycle precept of operation, its operating precept is sometimes referred to as reverse cycle conditioning or reverse-cycle refrigeration. The latter time period shouldn’t be correct because there are fundamental variations between the working rules of a heat pump and a real refrigeration unit. The confusion probably stems from the truth that during the cooling cycle, the operation of a pump is identical to that of the mechanical refrigeration cycle in a packaged air-con unit. The indoor coil function as an evaporator, cooling the indoor air. The outdoor coil is condenser, in which the new refrigerant gas releases heat to the outside air.

Heat Pump Working Ideas

The 2 principal phases of heat pump operation are the heating and cooling cycles. A third section, the defrost cycle is used to guard the coils from extreme frost buildup.

Heating Cycle

The heating cycle of a heat pump begins with the circulation of a refrigerant by the outside coils. Initially, the refrigerant is in a low-pressure, low-temperature liquid state nevertheless it soon absorbs enough heat from the outdoor air to lift its temperature to the boiling point. Upon reaching the boiling level, the refrigerant modifications into a sizzling vapor or gas. This gas is then compressed by the compressor and circulated under high pressure and temperature by means of the indoor coils, the place it comes into contact with the cooler room air that circulates around the coils. The cooler air causes the gas to chill, condense and return to the liquid state. The condensation of the refrigerant vapor releases heat to the interior of the structure. After the refrigerant has returned to a liquid state, it passes by way of a special pressure-reducing gadget and back through the coils where the heating cycle starts all over again.

Cooling Cycle

Within the cooling cycle, the reverse valve causes he move of the refrigerant to be reversed. In consequence, the compressor pumps the refrigerant within the opposite direction in order that the coils that heat the building or house in cold climate cool it in warm weather. In different words, the heat is extracted from the interior, cycled through the heat pump after which expelled outside the building or area throughout the condensation of refrigerant.

Defrost Cycle

Because the outdoor air is relatively cool when the heat pump is on the heating cycle, and the outside coil is acting as an evaporator, frost varieties on the surface of the coil underneath sure conditioners of temperature and relative humidity. Because this layer of frost on the coils interferes with the efficient operation of the heat pump, it should be removed. This is achieved by putting the pump via a defrost cycle.